Specifications
- Power:
- 220/110VAC 50/60Hz Single Phase
- 3 Amp @ 110VAC
- CDA/N2 :
- 75 to 90 psi
- Grounding:
- Single Point Low Impedance VAC (provided)
- Exhaust:
- 1.25″ Diameter port; 5 CFM max (non-process)
- Wafer Size:
- 3” (75 mm) thru 8” (200 mm)
- Weight:
- ≈ 70 Lbs.
- Dimensions (W x D x H):
- 75mm thru 150mm (3″thru 6″): 17″ x 14″ x 32″
- 200 mm (8 inch): 17” x 24” x 47”
Options
- Recessed mounting
- Vespel package for high temperature applications
- Stainless steel covers
- Hot boat sensor
Features & Benefits
- Horizon Junior 2-Stage Series V will transfer a maximum of 25 wafers between two cassettes, two process boats or one process boat and one cassette.
- PLC controlled enhancing system simplicity.
- As with all Mactronix wafer transfer systems, the Horizon Series may be configured to accommodate a wide range of Plastic, Teflon®, Metal, Quartz, Silicon Carbide, and Polysilicon carriers.
- With the push of a button, the machine transfers wafers automatically.
- Stage shifts for easy loading and unloading of carriers and boats.
- The Horizon Series V machines are designed to limit particle contamination by using rod-less cylinders, “clean room grade” rails and bearings and electric boat sensors.
- The machine will not introduce more than 1.5 particles, greater than .23 micron in diameter, per wafer per transfer (machine must be exhausted to achieve this figure).
- All aluminum parts are hard black anodized for corrosion resistance.
- Electronic through beam sensors are used to detect wafer presence in boats and retainers thus preventing accidental double loading and scratches.
- Lift system uses ramped speed controls for gentle pick-up and landing.
- Pressure sensors are used for both personal safety and prevent wafer damage by inhibiting machine operation.
- Retainers default to closed position to prevent the dropping of wafers in the event of a power disruption or a loss of air pressure or both.
- A “Maintenance/Cleaning Mode” is provided to facilitate preventative maintenance.
- The Series V machines have been tested with up to 50,000 volts of electrostatic discharge without disruption to internal electronics. The Series V machines are virtually immune to RFI noise, EMF, and ESD.
- Uptime will exceed 99.25%.
- MTBF (mean time between failure): 2,500 hours
- MTBA (mean time between assist): 1,000 hours
- MTTR (mean time to repair): less than 1 hour
- PLC controller is equipped with an RS422 communications port.